Best 500 Lph RO Plant - 09717236111

Configuration of Best RO Plant 500 Lph basis of design and capacity.


OBJECT

To commission a Reverse Osmosis System to recover 500 liters of low TDS water per hour.



ASSUMPTIONS

No. Of working days: 360 days

No. Of working hours: 8 hours

Capacity utilization: 50%

INPUTS (Raw water Quality):

Total Dissolved Solids: 2000 PPM





Total Dissolved Solids: 100 PPM app*.

Flow rate:

Feed water: 1300 Lph

Treated water: 500 Lph

Reject water: 800 Lph (Depend on water property)

REVERSE OSMOSIS PLANT OF FLOW RATE 500 Lph.


Technical specification


1.

RAW WATER PUMP

Design To maintain the Dual Media Filter at pressure more than

2.0 bar, which is the min. operating demand for a filter.

Specifications

  1. MOC: FRP

  2. Type: Horizontal Centrifugal

  3. Flow Rate: 1500 liters per Hour

  4. Head: 20 m

  5. Power Required: 1 hp

  6. Electrical: 220 V, Single phase, 50 Hz

  7. Cycle: 2900 rpm

  8. Make: Wilo Germany/CRI

  9. Quantity: 1 No.



2.

DUAL MEDIA FILTER

Objective: To remove the total dissolved solids, dirt, iron and

Decrease silt thickness index which can pollute the membranes


Specifications Vessel

a) Make: PENTAIR/AVENTURA/ADWYN

b) The material of Construction: FRP

c) Diameter: 10 inches

d) Height: 54 inches

e) Testing Pressure: 10 kg/cm2

f) Opening: Top

g) Quantity: 1 No.



3.

VALVE

a) Make: Prahar, solo/ Canada/Midas, Germany

b) The material of Construction: High Strength PP

c) Type: Multi port Single lever value

d) Size: 1 inch

e) Maximum Flow Rate: 2,000 Lph

f) Working Pressure: 2-4 Bar

g) Working: Up-flow



4.

MEDIA

Mixed bed sand media consisting of the following

1. Gravel

2. Pebbles

3. Quartz Sand

4. Anthracite

Average Porosity 50-micron particulate size

Bed depth: 300 mm

Pipelines & Accessories:

Pipe of PVC 10 Bar tested pressure


5.

ACTIVATED CARBON FILTER

Purpose: To remove the total color, smell, and odor, from the water


6.

VESSEL

Specifications


a) Make: PENTAIR/AVENTURA /ADWYN

b) The material of Construction: FRP

c) Diameter: 10 inches

d) Height: 54 inches

Testing Pressure: 10 kg/cm2

e) Opening: Top

f) Quantity: 1 No.



7.

DOSING SYSTEMS

Purpose: To dose anti scalene chemical to protect the scaling

order on RO membranes.


Specifications

1. MOC: pp.

2. Capacity: 2 Lph

3. Pressure: 4 Bar

4. Qty: 1 No.

5. Make:

A) Edose

B) SEKO

C) Etatron DS

D) Adwyn

6. TANK 100 Ltr


8.

MICRON FILTER & HOUSING

Purpose: To remove the fine particles up to 05 microns and

reduce silt density index levels to an acceptable level.


Specifications

Cartridge Filter & Housing


Cartridge Filter

f) Make: Filtration

g) Cartridge MOC: Polypropylene

h) Length: 20”

i) Diameter: 2.5”

j) Quantity: 1 no.

k) Micron rating: 05 micron


Housing

a) Make: Big Blue

b) MOC of Housing: Frp

c) Length: 20”

d) Diameter: 4.5”

e) Quantity: 1 no.



9.

HIGH-PRESSURE PUMP

Purpose: To feed the Reverse Osmosis Membranes at a pressure

more than the osmotic pressure taking into consideration

flux rate, flow, and recovery.


Specifications

a) MOC: Stainless Steel

b) Type: Vertical Multistage

c) Flow Rate: 1300 liters per hour

d) Head: 120 miter

e) Power Required: 2 hp

f) Electrical: 440 V, three-phase/single phase, 50 Hz

g) Cycle: 2900 rpm

h) Make: Sumo/CNP/CRI



10.

RO MEMBRANE

Purpose: To eliminate the essential part of TDS up to 98% by


Reverse Osmosis Membranes prepared and designed

to give sufficient flow and recovery.


Specifications

a) Type: Spiral Wounded

b) The diameter of the Membrane: 4.0 inch

c) Length of Membranes: 1 Mt.

d) No. of Membranes: 2

e) Recovery per Membrane: 15-17%

f) Salt Rejection per Membrane: 90-98%

g) Make of Membranes: Dow/Hydranautics /Burton/CSM

h) System Recovery: 45-50%


11.

RO PRESSURE TUBE

Purpose: To pack RO Membranes and operate at

huge pressure up to 400 psi


Specifications

a) MOC: FRP

b) The diameter of the Pressure Vessel: 4.2 inch

c) Length of Pressure Vessel: 2.2 m

d) No. Pressure Vessels: 2

e) No. of Membrane per Vessel: 1

f) Make: Maxima /Wave Cyber/Code line, /ALFA AEROSOL

g) Position: Horizontal Series

h) Arrays: 2 No.


12.

RO CLEANING SYSTEM

Purpose: We provide a flushing method, which shall help to

clean the membrane and get rid of the pretentious that

get deposited on the membranes.


Specifications

a) Flushing Time: 15 minutes

b) Flushing Media: Treated Water/Chemical

c) Flushing Tank Size: 100 L

d) Tank MOC: HDPE

e) Flushing Pump: Common SS Pump for raw water and flushing

f) Semi-automatic with two ball valves operation



13.

ELECTRIC PANEL

Purpose: A control panel is provided as a safety measure and automation work for the pumps & other electrical parts.


Specifications

a) Complete Starters, Overload relays and single-

Phase preventer for the pump.

B) Volt Metter, Ammeter, Mcb's, Indicating lights

c) Push buttons

d) Rocker switches for dossers

e) Incomers, Auto-Manual Switches


14.

Instrumentation

a) Flow Meter: To regulate the online flow of water

b) Pressure Gauges: For calculate pressure for each unit in Reverse osmosis system


Rota Meter

Quantity: 2 Nos. (Permeate & reject line)

Range: 2.0 cu.m. Per hour

Make: Adwyn


Pressure Switch

Quantity: 2 No. (Low & High)

Range: 0-450 psi

Make: Indfos, India


Pressure Gauges

Quantity: 2 No.

Range: 0-7 bar

Dial Size: 2.5 inches

Type: Bourdon

Make: as available


#Product